
Add to Cart
4-20mA RS485 C2H4 Single Gas Detector 0-1000ppm Ethylene Test Monitor For Fruit Vegetable Room
For some fruit and vegetable industrials, they need to test C2H4 ethylene leakage or C2H4 ethylene concentration during ripening process. To make sure safety or fruit and vegetable quality, it is very important to test C2H4 ethylene. If you want to test C2H4 ethylene leakage or residual, we suggest you use measure range 0-50ppm or 0-100ppm; If you want to test C2H4 ethylene concentration during ripening process, we suggest you use measure range 0-500ppm or 0-1000ppm. Besides, our 4-20mA RS485 C2H4 Single Gas Detector can be with controller panel, it can be connected with detectors, the readings will show on the panel by 4-20mA or RS485 signal output. The 4-20mA RS485 C2H4 Single Gas Detector and controller panel have alarm functions, if there have any leakage or higher than alram concentration you set, it will alarm with sound and light. With relay output, once the concentration exceed the preset alarm point(threshold), it will start the acoustic-optical alarm on the central unit and drive the external equipment like exhaust fans.
Nursery, farm;
Cold storage;
Agricultural Research Institute;
Chemical plant;
Gas Station, gas pipeline, Chemical medicine, Metallurgy field, etc
4-20mA RS485 C2H4 Single Gas Detector Specification
Gas detected | C2H4 Ethylene | ||
Detection principle | Electrochemistry, PID, Catalytic combustion, sensor and ic are imported from UK | ||
Install method | Wall-mounted, piping type, flow-type (according to the detected environment) | ||
Measure range | 0-10ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-100%LEL | ||
Resolution | 0.001ppm, 0.01ppm, 0.1ppm, 1ppm, 1%LEL | ||
Precision | ≤± 2-3% FS for normal sensor, ≤± 1% FS for high precision sensor | ||
Signal output | 4-20mA, 0-5V, RS485, relay(optional) | ||
Response time | ≤10S | Recovery time | ≤10S |
Repeatability | ≤±1% | Linearity error | ≤±1% |
Zero shift | ≤±1%(FS/year) | Display | High-light nixie tube display |
Connection mode | G1/2 external thread explosion-proof flexible pipe | Unit | %VOL |
Temperature | -20 to 50°C | Humidity | 0-95%RH |
Explosion-proof | II 2G Ex db IIC T6 Gb IP65 | Degree of protection | IP65 |
Alarm | Sound, light | Operating time | 24H |
Dimensions | 180*150*90mm | Weight | ≤2kg |
4-20mA RS485 C2H4 Single Gas Detector Advantages:
4-20mA RS485 C2H4 Single Gas Detector Features:
Factory information
Shenzhen YuanTe is gathered by a group of industry experts who are experienced in gas detectors R&D, manufacturing and investment. Every year, 5% of Shenzhen YuanTe’s income will be invested as R&D fund. To select out these new product, new technology and new services which will meet market demand is the most important task for R&D team.
For manufacturing, we have independent production workshop, modern production equipment, aging room, calibration room and professional staff.
For marketing, we implement flexible and competitive price and diversified sales strategy. We penetrate the market by various methods such as OEM, ODM, agent and direct selling, and ensure profit of every partner.
For service, we provide 24h/day service to users, rapid in response, technical guidance in place, convenience in repair and maintenance. At present, detectors are with ATEX CE EMC international certifications, Company has got ISO9001-2015 Quality management system certificate.
FAQ
Q: What is your terms of payment ?
A:We accept VISA, MasterCard and TT.
Q: When do you reply to messages?
A: We are on line 24*7.
Q: What is the warranty for your product ?
A: 12 months or 24 months, Lifetime maintenance for 4-20mA RS485 C2H4 Single Gas Detector.
Q: When do you send the products? And how do you send it ?
A: For the small order, we will send out the goods with 1-2 days, If have stock ,we will send immediately.
We send 4-20mA RS485 C2H4 Single Gas Detector by ups, fedex, tnt or dhl.
For big order, such as: 100ppm, 200ppm, 4-20mA RS485 C2H4 Single Gas Detector will be ready in 15 days.
Q:Do you accept OEM or revised logo, color, model, size?
A:Yes, we accept OEM.
We can make 4-20mA RS485 C2H4 Single Gas Detector according to customer personal requirement.
Q: How about the quality of the managements ?
A: We have a complete quality control system , 4-20mA RS485 C2H4 Single Gas Detector will be fully pre-inspection by QC departments before shipping to you . We have the certification of ISO,CE, ATEX. And we can send the certification test of our company to you.
Q: How about your after-sale service?
A: After sending, we will track 4-20mA RS485 C2H4 Single Gas Detector for you , until you get 4-20mA RS485 C2H4 Single Gas Detector.
When you got 4-20mA RS485 C2H4 Single Gas Detector, test 4-20mA RS485 C2H4 Single Gas Detector, and give me a feedback.
If you have any questions about the problem, contact with us, we will offer the solve way for you.
Contact Information
Celia Wu
SHENZHEN YUANTE TECHNOLOGY CO.,LTD(Safegas)
Mobile/WhatsApp/Wechat: +86 15889417475
Email: sales04@szyuante.com