Shenzhen YuanTe Technology Co., Ltd. (Safegas)

Shenzhen YuanTe Technology Co., Ltd(Sagegas) Specialized in gas detection for 16 years

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Single Gas Detector /

Ozone PPB Level Meter High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room

Contact Now
Shenzhen YuanTe Technology Co., Ltd. (Safegas)
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MsCloris Wang
Contact Now

Ozone PPB Level Meter High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room

Ask Latest Price
Video Channel
Brand Name :YuanTe
Model Number :YT-96H
Certification :CE ISO9001-2015
Place of Origin :China
MOQ :1
Price :Negotiable
Payment Terms :T/T, Western Union, Credit Card
Supply Ability :500PCS/DAY
Delivery Time :2-3 days
Packaging Details :Carton Box
Detected Gas :Ozone
Measure Range :0-1000ppb, 0-1ppm, 0-5ppm, 0-10ppm, 0-20ppm, 0-50ppm, 0-100ppm
Sampling method :Diffusion
Detection principle :Electrochemical
Install Method :Wall mounted
Display :Segment LCD
Power supply :24V DC
Signal output :4-20mA&RS485
Material :Flame Retardant Thermoplastic PS
Weight :230g (without packaging)
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Ozone PPB Level Meter For Safe High Precision UK Sensor Ozone Alarm Tester

Product overview

YT-96H-WH is specially designed for disinfection field like medicine clean room. It’s an online monitoring fixed ozone detector. Using imported brand electrochemical principle sensor, it’s small and light, fast response, accurate detection, reliable operation and convenient for maintenance. 24V DC power supply, standard 4-20mA, RS485 signal and a set of relay signal output. It’s non-explosion-proof design, so need to be installed in non-explosion-proof workplaces.
Product Advantages
All use imported brand electrochemical principle sensors
Standard three-wire 4-20mA analog signal, RS485 signal output
Compatible with various control panels, PLC, DCS and other control systems, can realize remote monitoring
A set of relay signals is standard equipped, and can control peripheral sound and light alarms, fans, solenoid valves and other equipment
Setting, calibration and remote monitoring can be realized by the upper software.

Ozone PPB level Meter Specification

Detected gas:
Ozone, etc, according to customer's requirements.
Detection principle:
Electrochemical
Measure range:
0-1000ppb, 0-1ppm, 0-5ppm, 0-10ppm, 0-20ppm, 0-50ppm, 0-100ppm, etc, according to customer's requirements.
Resolution:
1ppb, 0.001ppm, 0.01ppm, 0.1ppm, 1ppm, etc, according to sensor and measure ranges.
Accuracy:
≤±1-2%F.S.
Response time:
≤30 seconds (T90)
Display:
Segment LCD
Shell material:
Flame Retardant Thermoplastic PS
Concentration unit:
ppm, mg/m3
Alarm mode(Optional):
Buzzer and light, high and low alarm values can be set by customer.
Signal output:
4-20mA, RS485, 1 set of relay output; 1-5VDC(optional)
Communication and data download:
With PC software, history data can be downloaded, stored, printed, and analyzed in computer (optional)
Installation method:
Wall-mounted
Power supply:
24VDC
Language:
English
Humidity:
0~95%RH (non-condensing)
Temperature:
-20℃~+50℃
Working pressure:
91~111kpa
Size:
80.2*145*62.2mm
Weight:
230g (without packaging)

Ozone PPB Level Meter High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room

Ozone PPB Level Meter High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room

Ozone PPB Level Meter High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room

Accessories & Configuration list
Standard accessories
1. One fixed gas detector
2. One calibration cap
3. An instruction manual
4. A certificate of conformity
Optional accessoires
1. 24V DC adapter
2. Alarm light

The following points should be noted when using ozone detector

1. The "Industrial Hygiene Standard" formulated by the Ministry of Health of in 1979 stipulates that the safety standard of ozone is 0.15ppm.
2. The American standard stipulates that personnel can work for 8 hours at a concentration of 0.1ppm. (The ozone concentration in general forest areas can reach 0.1ppm)
3. The International Ozone Association stipulates that the professional indoor application of ozone is allowed to work for 10 hours at a concentration of 0.1ppm.
4. The concentration that causes a certain reaction of personnel is 0.5-1ppm, and the allowable contact time is 1.5 hours. After a long time, worker will feel discomfort such as dry mouth.
5. The concentration of 1-4ppm will cause coughing, and the allowable contact time is 1 hour.
6. The concentration of 4-10ppm will cause a strong cough, the allowable contact time is 20 minutes.
7. The half-life of ozone is 20-50 minutes, and the final decomposition product is oxygen, so there will be no residual contamination to food.